  condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com model pwr output #1 output #2 output #3 output #4 dbx-273-0512 275 +5v @ 50a +12v @ 8/12a pk -12v @ 4a dbx-274-1205 275 +5v @ 50a +12v @ 8/12a pk -12v @ 4a 5.2v @ 2 a dbx-274-1224 275 +5v @ 50a +12v @ 8/12a pk -12v @ 4a 24v @ 1.5a 24/28 vdc input ?multiple output model pwr output #1 output #2 output #3 output #4 dct-253-0512 250 +5v @ 30a +12v @ 5a -12v @ 5a dct-353-0512 350 +5v @ 45a +12v @ 6a -12v @ 6a dcx-353-0512 350 +5v @ 50a +12v @ 8/12a pk -12v @ 4a dcx-354-1205 350 +5v @ 50a +12v @ 8/12a pk -12v @ 4a 5.2v @ 2a 48 vdc input ?multiple output these series are particularly suitable for critical, ?an? fail? mobile; or transportable systems. all models share the same foot- print and can include current sharing for redundancy (consult factory for details). optional dc power fail, covers, and fan/cover assemblies are available. these series are form-fit compatible with the 9?sc, max, mtc, and mps series DCT-250 dbx-275 dct-350 dcx-350 featuring: over 3 watts/in 3 power density meets international safety requirements all outputs regulated 1% high peak currents for motor starting system air and self-cooling options available in dual ac input range standard dbx series standard dct, dcx series option f option c 250, 275, 350 watts multiple output 24/28 and 48 vdc input
condor d.c. power supplies, inc., a subsidiary of sl industries, inc. 805-486-4565 ?(800) 235-5929 fax: (805) 487-8911 http://www.condorpower.com function location notes connector output #1 terminal marked +v main output terminal marked -v rtn (common) output #2 tb2-3 (if provided) tb2-4 rtn (common) output #3 tb2-5 (if provided) tb2-4 rtn (common) output #4 tb2-1 (+) floating output (if provided)) tb2-2 (? floating output specifications: all models input dc input: db, dbt, and dbx models 20-32 vdc range, internally fused for 20 a. dc, dct, dcx, and dps models 40.8-60 vdc range, internally fused for 15 a. efficiency: 70 to 75% typical. output adjustability: all outputs user adjustable ?% minimum. line & load reg: ?% over dc input range and 0 to 100% load change, except dps models hold ?% on +5 v output (preprogrammed slope). multiple output units require a minimum load of 10% on the +5 v output when drawing full load on the auxiliary outputs. ripple & noise: less than 1% p-p or 100 mv, whichever is greater. remote sense (output #1) : compensates for 250 mv total line drop. open sense lead protection. (see redundancy, below.) temperature coefficient: 0.02% per degree c. stability: 0.1% over 8 hours after 30 minutes warm-up. transient response: output voltage returns to within 1% in less than 500 ? for a 50% load change. peak transient does not exceed 5%. overload protection: all outputs are protected against overload and short circuit. automatic recovery upon removal of fault. overvoltage protection (output #1) : protects load against power supply induced overvoltage. trip point is factory set so that output voltage cannot exceed 136% of nominal. peak output current: dual current ratings define continuous and peak currents. the peak current shown can be delivered for a maximum period of 30 seconds. remote inhibit: contact closure to the negative sense line drops output power to nominal zero. redundancy (dps only): external or-ing diodes and slope program current sharing on output #1 provide ?+1?capability. remote sense (+s) compensates for additional 0.6 v diode voltage drop. current sharing remains within 10% of the units full output current rating. reverse voltage: protected against reverse voltage up to supply current rating. environmental thermal protection: shuts down power supply if overheated. automatic recovery. temperature range: 0 to 50? at full ratings. safety agencies: most models are approved to ul1950; csa 22.2 #234; iec 950 and t?v en60950, class 1 selv., ce 72/23/eec/93/68eec (low voltage directive). conducted rfi: meets fcc part 15, subpart j, class a; en55022 class b; cispr 22 class b. cooling: 30 cfm required to achieve full ratings. output isolation: isolated from ground 50 vdc, except 100 vdc for models rated 48 vdc output. 250, 275, 350 watts 9? 5x 2.5 DCT-250,350, dbx-275, dcx-350 dc output barrier strip #6-32 screws 3/8?centers bus bars #10-32 screws function location notes connector j1-1(+ s) output #1 sense j1-2 (?s) output #1 sense rtn j1-3 reference to j1-2 inhibit j1-4 (ih) short to j1-2 *optional function status and control amp mta type #640456-4 pin header (locking) remote sense dc power good* function ?8 vdc +24 vdc connector tb1- ?8 vdc input +24 vdc return tb1- ?8 vdc return +24 vdc input tb1- safety ground safety ground barrier strip #6-32 screws 3/8?centers options: option ?? cover: limits contact with power supply interior. option ?? fan/cover assembly: cover with integral ball-bearing fan provides proper cooling to achieve full ratings at 50? ambient temperature. option ?? dc power good: provides a ttl ??open collector when output #1 is above 4.6 v nominal. option ?? fan/cover assembly: low profile, end venting cover with integral ball-bearing fan. consult factory for other available options. dc input dbx, dct, dcx with option f 3.8 lbs - 1.7 kgs dbx, dct, dcx 3.2 lbs - 1.5 kgs dimensions: inches millimeters () (+) ( )


▲Up To Search▲   

 
Price & Availability of DCT-250

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X